Skip to content

Home / Services / Cytokine profiling

VexisBio research services · San Diego

Cytokine Profiling Services.
Select 1–13 Cytokines.

Measure what matters. Select your human inflammatory cytokines for research reporting. We run the LEGENDplex™ Human Inflammation 13-plex assay and provide results for the targets you choose, with appropriate QC review and reporting qualifiers.

13 availableChoose your reported targets
Your selectionReport only ordered analytes
RUOResearch use only
Thirteen cytokine targets connected to a bead-based assay, flow readout, and reviewed data
One established multiplex assay. Reporting tailored to your selected cytokines.

A profile, with perspective

Connect your experimental conditions to an inflammatory response.

Use multiplex measurements to explore immune responses, compare treatment conditions, or prioritize cytokines for follow-up. We scope the panel, sample handling, dilution strategy, and analysis around your study.

01 / STUDY PLANNING

Start with the biological question

Choose the cytokines to be reported, then define the sample matrix, groups, expected signal range, and study question.

02 / ASSAY EXECUTION

Run the multiplex assay

Run the established multiplex kit, classify the bead populations, and evaluate the requested cytokines against their standards.

03 / DATA REVIEW

Keep the qualifiers attached

Review bead counts, calibration, duplicate agreement, and results outside the usable range before drawing conclusions.

Research applications

Focused cytokine insights for your study design.

Use project-selected human cytokine readouts to explore immune activation and inflammatory signaling in research samples.

IMMUNOLOGY

PBMC stimulation studies

Compare research conditions, stimulation controls, and time points in PBMC culture supernatants.

IMMUNE RESPONSE

Peptide-response research

Explore cytokine patterns in peptide-stimulated cultures with appropriate biological controls and replicate design.

DISCOVERY

Inflammation & drug discovery

Profile selected cytokines in inflammatory models and immunomodulatory compound research.

Featured panel

Choose from 13 human inflammatory cytokines.

Select one, several, or all of the available targets below. We use the LEGENDplex™ Human Inflammation Panel 1 for the assay and include only your agreed, ordered cytokines in the results report.

Cell culture supernatants are our initial service focus. Serum, plasma, and other matrices require a project-specific feasibility review before acceptance. This panel targets human cytokines; other species require separate review.

Panel availability, matrix suitability, sensitivity, and reportable ranges are confirmed for each project. LEGENDplex is a trademark of BioLegend; this service listing does not imply manufacturer endorsement.

Available targets for your order

  • IL-1β
  • IFN-α2
  • IFN-γ
  • TNF-α
  • MCP-1
  • IL-6
  • IL-8
  • IL-10
  • IL-12p70
  • IL-17A
  • IL-18
  • IL-23
  • IL-33

Select your requested targets in the quote form. Each reported analyte has its own calibration and reporting limits.

Before samples ship

Plan the samples before you run the plate.

Send us your matrix, sample count, available volume, and anticipated concentration range. We will confirm the required volume, handling conditions, and shipping plan before you send material.

Cell culture supernatants

Our initial service focus includes PBMC and other cell culture supernatants. Please provide the cell system, medium, stimulation conditions, sample groups, and collection time points.

Serum and plasma

Available for project discussion, subject to feasibility and matrix acceptance review. Additional dilutions or controls may be needed for high-abundance targets.

Other matrices or existing FCS files

Contact us for feasibility review or analysis-only scope. Existing data require a plate map, kit and lot information, standards, and dilution records.

Available volume should cover the agreed replicates, handling allowance, and any planned dilution or rerun reserve. Exact requirements and sample acceptance are confirmed in your quotation.

How we work

A clear path from sample plan to report.

  1. Scope

    Confirm your ordered cytokines, matrix, sample identifiers, study design, and deliverables.

  2. Run

    Prepare standards, apply agreed dilutions, and acquire bead-based flow cytometry measurements.

  3. Review

    Assess bead classification, event counts, calibration behavior, and duplicate precision.

  4. Report

    Report the ordered cytokines with units, dilution corrections, relevant qualifiers, and follow-up recommendations.

What you receive

Results you can trace back to the measurement.

Your report covers the cytokines listed in your agreed order. Results for other targets in the kit are not included unless they are added to the project scope. Your agreed package can include:

  • Concentration tables for your ordered analytes, with units and dilution factors.
  • Replicate fluorescence, bead counts, and duplicate CV summaries.
  • Standard curves and calibration review.
  • Flags for results below detection, below quantification, or above the upper range.
  • Summary figures and study-group comparisons when supported by the design.
  • Machine-readable results for the ordered analytes, as agreed in the project scope.
Discuss your reporting needs →

Common questions

Scope the work with confidence.

Can I order only some of the cytokines?

Yes. Choose one, several, or all of the 13 available cytokines. We use the existing multiplex kit for the assay and report only the cytokines confirmed in your order. Unordered analyte results are not included in your report.

Is this a newly manufactured custom assay kit?

No. Customization means choosing the analytes to be reported from an established multiplex kit. It does not mean manufacturing a new kit or changing its antibody and bead formulation.

What sample volume do I need?

We confirm volume after reviewing the matrix, panel, number of replicates, dilution plan, and material needed for handling or reruns. Please tell us the available volume per sample before shipping.

Can you analyze existing flow cytometry files?

Yes, analysis-only projects can be reviewed for scope. Send a description of the FCS files together with the plate map, kit catalog and lot, standard concentrations, sample dilution factors, and sample key. File compatibility and data completeness are checked before acceptance.

What happens if a cytokine is above the standard curve?

We retain the over-range qualifier. If a quantitative result is needed, an additional dilution and rerun may be appropriate. Additional testing, material requirements, and charges are agreed before that work begins.

Can you compare treatment groups?

Yes, when group assignments and the number of independent biological replicates support the requested analysis. Technical duplicate wells are not counted as independent biological replicates.

How much does the service cost, and how long does it take?

Pricing and turnaround are quoted for the complete project, including sample count, requested reporting targets, kit use, matrix, replicate design, analysis, and any pilot or dilution work. Selecting fewer reported cytokines does not necessarily reduce kit use or assay cost proportionally.

Is this a clinical diagnostic test?

No. This service is for research use only and is not intended for diagnostic procedures, patient management, or clinical decision-making.

Start a project

Tell us what your cytokine study needs to answer.

Select the cytokines you want reported and share the sample type, sample count, and timeline. We will confirm the requested reporting scope and prepare a project-specific quotation.

info@vexisbio.com
+1 (619) 675-5388
San Diego, California

This form prepares an email in your email application. Review it, add any appropriate attachments, and send it to submit your inquiry.

For research use only. Project-specific methods, acceptance criteria, and deliverables are defined in the agreed scope.

Select cytokines to be reported *

Choose at least one. We run the multiplex kit and report only your ordered targets.

0 selected

Please do not include patient-identifying or confidential information in this email form.